Projects
Back
Deadline for applications: Tuesday 19 January, 13:00 (UK time)
Data-Driven Self-Sensing Soft Pneumatic Compression for Personalised and Adaptive Monitoring
Project background
Soft wearable robots and compression devices physically interact with the human body, yet the body is not a fixed or fully known mechanical environment. Joint dimensions and soft-tissue properties vary between people and can also change within the same person over time, particularly in conditions associated with swelling. This creates a fundamental challenge for wearable systems: the same actuation can produce different physical effects depending on the individual and their current physical state.
Current compression systems typically rely on external measurements to determine device size or on pressure sensing to adjust the applied compression. These approaches can achieve a desired pressure, but they provide limited information about the body being compressed. The interaction between a soft pneumatic device and the body, however, contains information about the underlying morphology and mechanical behaviour. Understanding and exploiting this interaction could allow a wearable device to both deliver compression and learn about the person using it.
This project builds on recent preliminary research in which a soft pneumatic ring with distributed force sensing was developed to compress a finger joint while simultaneously estimating its size from the device’s own interaction response. The study demonstrated that joint size can be estimated from pneumatic and sensor measurements and that this information can be used to predict the actuation required to achieve a target contact pressure. It also showed that contact pressure can vary substantially around the joint, even when the mean pressure is the same, highlighting the importance of distributed sensing.
The PhD will investigate whether this interaction can provide richer and more reliable information about the changing state of the body. The student will combine pneumatic pressure, injected volume and distributed contact-pressure measurements with repeated measurements of joint morphology to develop personalised models of human–device interaction. The research will then investigate whether changes in these interaction signals can be used to monitor changes in morphology, swelling and soft-tissue behaviour over time, and whether this information can support adaptive and closed-loop compression. The project will progress from controlled laboratory experiments through healthy-participant studies towards patient-centred evaluation and translation.
The intended outcome is a data-driven, self-sensing soft pneumatic compression system that can move beyond simply applying a prescribed pressure. Instead, the device will investigate how a wearable system can measure, learn and adapt from its physical interaction with the individual, while maintaining appropriate uncertainty estimation, safety constraints and human oversight.
Project aims and objectives
The project aims to determine whether the interaction between a soft pneumatic compression device and the human body can provide reliable information about an individual’s changing mechanical state, and to use this information to develop personalised and adaptive compression. The student will:
- characterise how pneumatic input and distributed contact-pressure responses vary with joint morphology and mechanical properties, and identify interaction features that provide reliable information about the state of the compressed joint.
- develop and validate personalised interaction-based models to estimate joint morphology and relevant mechanical characteristics, and determine whether these estimates can predict the pneumatic input required to achieve a target contact pressure across individuals and repeated sessions.
- investigate whether changes in interaction responses over time can provide information about changes in joint morphology, swelling and soft-tissue behaviour, and use these findings to develop personalised and closed-loop compression strategies that account for spatial pressure distribution and uncertainty.
- evaluate the usability, feasibility and potential clinical value of the self-sensing compression approach through co-design and human evaluation with relevant clinicians and people with lived experience.
Suitable background
We welcome applicants from biomedical engineering, mechanical engineering, robotics, computer science, health data science, artificial intelligence, electrical/electronic engineering or related quantitative disciplines. Applicants with an engineering, robotics or data-science background are particularly encouraged.
A strong foundation in programming, experimental design, sensors and instrumentation, signal processing, machine learning, soft robotics, pneumatic systems or biomechanics would be advantageous. Applicants do not need to have experience across all of these areas. Clinical, rehabilitation or healthcare experience is welcome but not essential, as interdisciplinary training will be provided throughout the project.
Skills and experience provided
The supervisory team combines complementary expertise in AI, computer vision and adaptive wearable robotics (Dr Letizia Gionfrida), clinical rheumatology and health data (Prof James Galloway), and medical devices and soft robotics (Dr Lukas Lindenroth). The student will work across soft robotics, sensing, data science and healthcare, gaining experience in the design and fabrication of soft pneumatic wearable systems, distributed force and pressure sensing, pneumatic control and experimental characterisation of human–device interaction.
The project will provide substantial training in data engineering and AI, including reproducible data pipelines, signal processing, feature extraction, statistical and machine-learning modelling, temporal analysis, personalised modelling, model validation, uncertainty estimation and out-of-distribution detection. The student will also develop experience in adaptive and closed-loop systems, including the use of distributed sensing to support personalised compression.
Through co-design and human evaluation, the student will gain experience in patient and public involvement, usability evaluation, human-centred medical-device development and clinical translation. Training will also cover research ethics, UK GDPR and health-data governance, risk management and responsible AI, including transparency, reproducibility, uncertainty, accountability and human oversight.
The student will be part of the DRIVE-Health CDT cohort, gaining access to interdisciplinary data-science training, leadership and entrepreneurship activities, healthcare-focused training and a three-month placement. The project will provide an opportunity to develop expertise at the intersection of soft robotics, wearable sensing, artificial intelligence and personalised healthcare, with applications extending beyond compression therapy to other physical human–robot interaction and assistive technologies.